To install the roof wall flashing above the builder bent the top edge of the flashing into a 90 degree lip about 2 cm in width.
Stucco roof to wall flashing detail.
It should tuck under the sheathing wrap above and over the flashing below.
Roof sealants mastics.
Applying flashing to a stucco roof or walls requires both cement and nails as well as caulk or more stucco to create a water tight seal.
All exterior wall coverings whether it is wood siding vinyl siding brick or stone veneer stucco etc.
Flashing wall details faqs questions answers posted originally at this page.
That lip is then set into a reglet or groove in this case cut into the mortar joint of the brick wall above.
Control joint at floor line 2016 detail.
Stucco parapets 2020 detail.
Slip the wall leg of the weep screed behind the existing paper.
Flashing a nail flange window 2018 rev detail.
Above a lower roof where it abuts the wall.
In this video kirk giordano demonstrates how to counter flash the bottom of a stucco wall over the step flashing of the roof so that no one has to jackhammer your walls just to fix a roof.
Lay 2x4 blocks on the roof to set a consistent height for the weep screed flashing.
In all cases make sure to detail the flashing membrane so that it sheds water.
Typically made of aluminium or galvanized steel flashing is any material used over joints in your walls or roof to prevent water from seeping through.
Wall to roof deck flashing 2020 detail.
Under the eaves of a roof with little overhang and no gutters.
A critical component of step flashings along the run of the roof slope is a kick out flashing.
Must be kept up off the surface of the roof a minimum 1 some manufacturers of exterior wall coverings require a minimum of 2.
Where an attached backyard deck meets the house.
Roof to wall intersections.
Kick out flashing for stucco 2019 detail.
Rain splash up siding damage for more details about splashback or splash up water damage to exterior walls see.
Suggested citation for this web page.
The kick out flashing directs water away from the adjoining wall and ensures that the step flashing is not concentrating water on the surface of that wall.
The bottom leg of the step flashing is placed over the roof drainage plane.
There have always been problems with the flashing details at head walls rake walls and chimneys especially if stucco brick or stone veneer is used.
Flashing roof wall snafu for examples of roof wall abutment flashing foul ups to avoid.
Corners for stucco 2020.